PCB Vias: What The Hole Carries And Costs
Home
Yiwu, Zhejiang, China
Mon – Fri 9:00 AM – 6:00 PM · Sat 9:00 AM – 4:00 PM
[email protected]

What Is A Via In PCB: A Hole That Only Has To Be A Wire

Alan Xiao, Founder of Sourcing Pioneer
Alan Xiao Founder of Sourcing Pioneer
· Updated November 10, 2026 · 9 min read

A via is a plated hole joining two copper layers.

It carries no component. Nothing is soldered into it. Its whole job is to move a signal or a current from one side of the board to the other.

That sounds simple, and it is why vias are the last thing anyone checks. They are also the place where a board fails in a way you cannot see from the surface.

This page covers what a via is made of and which kinds your stackup can have. It also covers what the hole can carry, and why the count moves the price.

Studio still life of a small multilayer board edge showing plated holes on beige
Small holes, strict tolerances.

The Short Answer

A via is drilled through the board, then plated so the hole wall becomes a conductor. Two pads, one at each end, join that tube to the copper it serves.

It is not the same as a plated through hole, even though both are drilled and plated. A plated through hole is sized for a component lead, or for a screw. A via is sized for current alone.

The distinction matters on an order, because the two are drilled with different tools and checked against different rules.

Barrel, Pad, Antipad

Three names cover the whole structure, and each one can fail on its own.

The barrel is the plated tube inside the hole. Its thickness sets how much current the via can pass and how long it lasts under thermal cycling.

The pad is the copper ring at each end. It has to be wide enough that a small drill misalignment still leaves a ring all the way round.

The antipad is the clearance in every layer the via does not connect to. Too small, and the via shorts to a plane it should avoid.

Of the three, the pad is where inspection looks first, and the barrel is where the failures come from later.

Four Kinds, And What Each Costs

The trade press uses four names. They differ in where they start and stop, not in what they do.

KindWhere it runsWhat it costs
ThroughTop to bottom, open at both endsCheapest, one drill pass
BlindSurface to an inner layer, open on one sideExtra lamination step
BuriedInner layer to inner layer, open on neither sideExtra lamination, checked by section
MicroviaUsually one layer deep, laser drilledLaser tooling and tighter alignment

A through via wastes the layers it passes through, because it needs a clearance in each one. On a dense board that waste is the reason people pay for blind and buried.

A microvia is not simply a smaller through via. It is made with a laser, one dielectric layer at a time, which is why high density boards are built up rather than drilled through.

There is also a fifth kind worth naming, because buyers meet it in power designs. A thermal via carries heat rather than signal, and it is usually placed in an array of about a dozen under a hot part.

Every via also costs board area, and that cost hides on power planes. A through via needs clearance in every layer it passes, and each clearance removes copper from the plane it crosses.

A plane dotted with a thousand clearances is a plane with less copper, so it carries current less well and runs warmer. That is the second reason dense boards pay for blind and buried vias, beyond the routing space.

Your Stackup Decides Which Vias Exist

A designer can draw a buried via in a few seconds. Whether it can be built depends on the order the layers were glued together.

Fabrication starts from a core, which is a finished double sided board. Extra layers are added on top of it, or below it, in separate press cycles.

Drill a hole after the first press and it can only reach the layers that exist at that moment. That is the rule behind every stacking option a board house will quote.

Stack two layers on top of the core and the useful vias become 1 to 2, 1 to 3, and a full through hole. Stack one above and one below, and the set changes again.

So the question is not “can you make a blind via”. It is “which blind vias does this stackup allow, and how many press cycles do they add”.

Diagram of a core with layers pressed above and below, showing which via spans are possible
What the press order allows, the drill can reach.

Once a board needs enough layers to justify that, it usually needs laser drilled microvias as well. The two decisions arrive together.

Backdrilling: A Blind Via Without The Press

There is a cheaper route to part of the benefit. A through via that only needs to reach layer three still has a long unused tube below it.

That stub is an antenna. At high frequency it reflects energy and spoils the signal.

Backdrilling removes it. After plating, a controlled depth drill takes the copper out of the lower part of the hole. What is left is a via that is physically through but electrically blind.

It costs a drill pass rather than a press cycle. That is why it appears in high speed designs, where a full blind and buried stack would be too expensive.

What A Via Can Carry

Vias carry current, and small ones carry little. The estimate starts with a cross section.

The tube is a cylinder wall, so its copper area is the circumference times the plating thickness. A 0.3 mm hole with 25 micrometres of plating gives about 0.024 square millimetres.

Compare that with a track. A 0.2 mm track on one ounce copper carries about 0.007 square millimetres. At this hole size the barrel is the wider path, not the narrow one.

Shrink the hole and the answer flips. A 0.1 mm laser microvia with the same plating carries roughly 0.008 square millimetres, which is the same as that track.

So the barrel is not automatically the weak link. It becomes one through a small hole or a thin plating, and both are things you write down.

That is also why power paths get several vias in parallel rather than one larger hole. And it is why an array under a hot part is a thermal decision, not an electrical one.

The current a given via can pass depends on the temperature rise you will accept, and on how the board is cooled. Ask the fabricator for that table at your plating thickness.

Do not accept a rule of thumb in amps per via. Two boards with the same hole and different copper weight behave differently. The difference shows up as a hot spot, not as a datasheet error.

Diagram comparing the copper cross section of a via barrel with a track on the same board
The barrel is a thin wall, not a solid wire.

Seven Ways To Seal A Via

An open via can trap flux, wick solder, or leave a bubble under a part. How it gets sealed is a written choice, and the industry numbers the choices.

IPC-4761 defines seven types. The names are dull, and the difference between them is what your assembly house can promise afterwards.

TypeWhat is done to the viaTypical reason
ITented, covered by mask on both endsKeep solder out of a normal via
IITented and coveredSame, with a tighter mask rule
III-a and III-bPlugged with non-conductive material, one side or bothStop wicking during assembly
IV-a and IV-bPlugged and covered with wet maskPlug plus a smooth surface
VFilled with non-conductive pasteRemove the cavity entirely
VI-a and VI-bFilled, then covered with dry film or wet maskFilled with a flat cover
VIIFilled and capped, overplated on both sidesA flat, solderable pad over the via

The practical rule is short. A via that sits inside a component pad has to end up flat and solderable, so it points at Type VII.

A via that merely sits near a pad needs Type I or II, and nothing more. Paying for filling everywhere is a common way to waste money on a quote.

So group the vias in the drawing. Normal vias, vias near heat, and vias inside pads are three groups with three answers.

Why The Via Count Drives The Price

Four things about a via cost money, and only one of them is the hole itself.

The first is the number of drill hits. Every hole is a tool stroke, and a panel with two thousand more hits costs more machine time.

The second is the press cycle. Blind and buried vias need the board built in stages, which is why they are quoted separately from a through hole design.

The third is alignment. Vias place the strictest demand on registration in the whole board, so a design full of small vias forces tighter process control at every step.

The fourth is inspection. Buried vias are inside the board, so proving they are right means a cross section, which is a destructive sample rather than a look.

None of that is a reason to avoid vias. It is a reason to ask for the count before the quote, and to group the special ones so the ordinary ones stay cheap.

How A Via Fails

A good via fails slowly, and the mechanism is worth knowing because it changes how you test.

Copper and the board material expand differently when heated. The mismatch strains the plated barrel up and down the hole, cycle after cycle.

Eventually the plating cracks, and the connection opens. It can happen after years in a product that cycles between hot and cold.

Misalignment fails differently and much earlier. If the drill or a layer sits slightly off, the via can connect to the wrong copper, and the surface still looks perfect.

That is why a fabricator checks the data before cutting, and why a cross section is the only honest proof for a buried via.

There is also a signal problem that never shows as a fault. A via is a discontinuity in the path, so it reflects part of a fast edge. On a slow board nobody cares; on a fast one it eats margin.

How You Prove It

The only honest proof for a buried via is a cross section. The board is cut, potted and polished, then examined under a microscope, which is why the sample is destroyed.

For vias you can reach, a continuity test catches an open. It does not catch a thin barrel, because a barrel with half the plating still passes at room temperature.

That gap is why designs that matter get cycled on purpose. The industry built a fatigue calculator from a round robin of test boards. It is used to compare design choices, not to certify a batch.

So the split on an order is simple. Ask what will be sectioned, and ask what will be cycled. A quote that answers neither is selling a hole, not a via.

Six Lines for the Order

These six turn a stackup picture into an instruction.

One. The via types and the layers each one spans, drawn rather than described.

Two. Hole size and the annular ring you will accept around each pad.

Three. Plating thickness in the barrel, written as a number.

Four. The IPC-4761 type for each group of vias.

Five. Which vias sit inside component pads, and whether they must be filled and capped.

Six. Whether backdrilling is used, and to which depth.

One naming slip is worth avoiding. A bare board is judged against the printed board standards, not the assembly one, and the body that publishes them keeps the two families separate.

Three reads help. The drill data that travels beside the layer images is the file that carries every one of these holes.

What the paste and the oven do to a filled via explains why a cavity under a pad becomes a void.

And the enquiry that carries these six lines is the format that keeps them together. For the finished product, the paperwork a finished board needs for Europe sits outside the fabrication quote.

Checklist panel of six lines to put on a bare board order covering vias
Six lines that make a stackup quotable.
VIA CHECK

Send me the stackup drawing or the quote that came back for it. I will check which via types the stackup can actually build, whether the filled ones are specified by IPC type, and whether the drill count explains the price.

Check The Stackup

Questions Buyers Ask

Is a via the same as a plated through hole?

No. Both are drilled and plated, but a plated through hole is sized for a component lead or a screw. A via only has to carry current between layers.

Why are blind and buried vias more expensive?

Because the board has to be pressed in stages. Each stage allows drilling only through the layers that exist at that point, so extra press cycles are added.

What does backdrilling do?

It removes the unused copper below the layer a through via needs. The hole is still physically through, but it behaves like a blind via and stops reflecting energy.

How much current can one via carry?

It depends on the copper cross section and the temperature rise you accept. Ask the fabricator for a table at your plating thickness rather than trusting amps per via.

What is IPC-4761 Type VII?

A via filled with non-conductive material and then overplated on both sides, which leaves a flat surface. It is the type that suits a via placed inside a component pad.

Can a via fail after the board is built?

Yes. Heating and cooling strain the plated barrel against the board material, and the plating can crack after many cycles. A misaligned via can fail much sooner, and invisibly.

Questions & Comments

We read every one and reply within 24 hours

If a board failed and someone blamed a via, send me the section photo. The barrel tells you whether it was made badly or cycled too hard.

Subscribe
Notify of
guest
0 Comments
Most Voted
Newest Oldest
0
Would love your thoughts, please comment.x
()
x