Brushless Motors: KV, KT and the Sensorless Trade
Home
Yiwu, Zhejiang, China
Mon – Fri 9:00 AM – 6:00 PM · Sat 9:00 AM – 4:00 PM
[email protected]

What Is A Brushless Motor: The Brushes Moved Into A Chip

Alan Xiao, Founder of Sourcing Pioneer
Alan Xiao Founder of Sourcing Pioneer
· Updated November 10, 2026 · 10 min read

A brushless motor has no sliding contact. A controller does the switching instead.

The motor itself gets simpler and the electronics get harder. That trade decides what you have to write on an order.

Two numbers describe the motor: KV and KT. They are inverses of each other, and most datasheets quote them in ways that cannot be compared directly.

This page covers what the brushes were doing and what replaced them. It also covers the startup problem that comes with the cheap solution, and how to state the constants so quotes line up.

Studio still life of a small brushless outrunner motor with its controller on beige
No brushes, one controller, two constants.

The Short Answer

A brushless DC motor is a synchronous motor fed from a direct current supply. A controller switches the current into the windings so the magnetic field rotates, and a permanent magnet rotor follows it.

In a brushed motor, a mechanical switch on the shaft does that job. In a brushless motor, transistors do it, and the rotor position has to be measured or inferred.

The payoff is fewer wearing parts and less sparking. The cost is a controller that must be matched to the motor, because it needs to know where the rotor is.

What The Brushes Were Doing

The brushes are a rotary switch. Segments on the shaft connect to windings. Two soft carbon blocks press on those segments and feed current to the right coil at the right moment.

That simple arrangement has four costs, and all four are why the part disappeared from anything sealed, fast or maintenance free.

CostWhat it does to a product
Sliding frictionSteals power, most of all from a small motor
Brush wearMakes dust and needs a service visit; rules out sealed units
Brush dropA voltage loss across the contact that turns into heat
Switching sparksRadio noise nearby, and a real hazard in explosive air

Remove the contact and the life limit moves to the bearings. The windings also move to the fixed side, where heat can leave through the housing instead of through the air inside.

That last point is why a brushless motor can be fully enclosed. There is nothing inside that needs an air path, so the housing can keep dirt out.

The Controller Took Their Job

The controller has three outputs, one per phase, and each can pull or push. That is enough to make a rotating field with six steps per electrical cycle.

To fire at the right moment it needs the rotor angle. There are two ways to get it, and the choice changes the price and the wiring.

ApproachHow it finds the rotorWhat it costs you
SensoredHall sensors or an encoder report the angleExtra wires and parts inside the motor
SensorlessReads the back EMF on the idle windingNo sensor wires, but no signal when still

Back EMF is the voltage the spinning magnet induces in the winding it is not being driven from. It rises with speed, which is why it tells you the angle once the motor is turning.

A simple controller can use comparators on the sensor signals. A more capable one uses a microcontroller and manages acceleration, speed and efficiency in software.

Diagram comparing a mechanical commutator with a three phase electronic bridge
The switch moved from the shaft into the drive.

The Startup Problem In Sensorless

Standing still, a sensorless motor produces no back EMF. There is nothing to read, so the controller has no idea which way the magnet points.

The usual answer is to start from an arbitrary phase and see what happens. If the guess is wrong, the rotor turns the other way for a moment before the controller catches up.

That is the brief backwards twitch people notice at power on. It is not a fault, it is the method. Some designs read winding saturation instead, to estimate the position without moving first.

Two things follow for a buyer. If the product cannot tolerate a short reverse movement, specify a sensored motor or a controller with a startup routine you have seen work.

And write the load into the brief. A small fan starts easily in any sequence; a pump with water in it does not.

There is a second failure worth knowing. Once running, the controller needs the back EMF to keep time. If the load stalls the rotor, the signal vanishes and a simple controller can lose step.

Better drives notice the loss and restart. That behaviour belongs in the brief too, because a jammed pump should not need a power cycle.

Three Shapes, One Principle

The magnets and the coils can sit in three arrangements, and the choice changes the torque at low speed.

In an inrunner the magnets are on the rotor and the windings surround them. It suits high speed in a slim body.

In an outrunner the coils form the centre and the magnet cup spins around them. That shape usually carries more poles, which gives more torque at low rpm.

The third type is flat. Stator and rotor plates face each other in an axial flux layout. That fits where there is no room for length but there is room for diameter.

In all three the coils stay still. That is the part that matters for cooling and for wiring, because nothing has to reach a spinning part.

KV Is A No-Load Number

KV is the speed constant. It is the unloaded speed divided by the peak voltage at the winding terminals. The result is quoted in revolutions per minute per volt, or in radians per second per volt.

Those two units differ by a factor, so a number without a unit tells you nothing. A motor quoted at 3,600 rpm per volt is the same motor as one quoted at 377 radians per second per volt.

The worked example makes the definition clear. An unloaded motor at 5,700 rpm per volt, fed 11.1 V, would turn at 63,270 rpm.

It will not reach that speed in practice, because friction and other losses take their share. The figure is a ceiling, not a promise.

Two details are worth memorising. The voltage is the peak value at the coils, not the RMS value. And the speed is the unloaded one, so a loaded motor always turns slower.

How it is quotedSame motor, three figuresWhere you see it
KV in rpm per volt3,600 rpm/VFan and hobby listings
KV in radians per second per volt377 rad/s/VSI datasheets and papers
KT in newton metres per ampAbout 0.00265 N·m/ALoad and current calculations

All three lines describe one motor. A quotation that mixes them without saying which is which is the reason two suppliers appear to disagree.

Diagram of the KV line showing unloaded speed against voltage and the limit where back EMF equals supply
A straight line until back EMF meets the supply.

KT Follows From KV

KT is the torque constant: torque divided by the current that produces it. Buyers often treat it as an unrelated figure. It is not.

In SI units the two are reciprocals. KT equals one over KV, so a motor with a high KV has a low KT and needs more current for the same torque.

That is why the choice runs opposite to intuition. A low KV part is the one that pulls a heavy load slowly. A high KV part spins fast and gives up torque.

The example in the reference works it through. At 3,600 rpm per volt, which is 377 radians per second per volt, KT comes out near 0.00265 newton metres per ampere.

Notice what that number does not depend on: the size of the motor. The same KV gives the same KT regardless of how big the part is, which surprises people who assume bigger means stronger per amp.

So a torque figure needs three conditions to mean anything. It is at the shaft, it is continuous rather than a short burst, and it comes with an ambient temperature.

Ask for all three, and the two quotes in your hand finally describe the same thing.

Same Motor, Different Winding

Here is the detail that explains a lot of confusing catalogue pages.

A motor can be wound with fewer turns of thicker wire, or more turns of thinner wire. That changes KV without changing the size or the ability to shed heat.

Ask for the winding data with the sample: turns, wire diameter and the connection pattern. Without it a factory can rebuild to the same frame and land on a different KV.

The reference puts it as a worked case. Twelve turns of single wire rewound as six turns of two parallel wires doubles KV. The size constant, KM, stays the same.

So the industry splits the two jobs. KM is used to pick the size of motor for an application, and KV is used to pick the winding inside that motor.

This is why two listings with the same frame and different KV are not two different motors. They are two windings of one design, and the torque per amp changes with the winding.

What It Adds To The Bill

A brushed motor is one part and two wires. A brushless motor is a motor, a controller and, usually, a way to know the rotor angle.

So the comparison is rarely motor against motor. It is a cheap motor that wears out against a dearer motor that does not.

That trade pays off fastest where a service visit costs more than the part: sealed units, ceiling fans, pumps in a plant room.

It pays off slowest in a low duty product that runs for a minute a day. There the brushes outlive the warranty anyway.

Write both numbers down. The motor price and the controller price together are the real comparison, and a sample quotes only one of them.

Add the spares question. A controller with a firmware revision nobody recorded is a motor you cannot replace in two years.

Heat Sets The Size

Power out is limited by heat. Too much of it weakens the magnets and cooks the winding insulation, and neither failure is repairable.

The efficiency gain over a brushed motor is not spread evenly. It is largest at no load and light load, where the sliding contact was a big share of the loss.

For a buyer that means the datasheet’s continuous rating is only meaningful with a mounting condition attached. In still air, in a sealed box, the same motor carries less.

Ask for the rating with the mounting and airflow written down. A number without them is a laboratory figure.

Brushless Or Stepper

The two look alike inside. Both have a permanent magnet rotor, both may carry a position sensor, and both can hold torque at zero speed.

The difference is the job. A stepper is built to stop at a defined angle and stay there. A brushless motor is built to keep turning.

That shows up in how they are driven. A stepper takes a pulse train and moves one step per pulse. A brushless motor takes a commutation sequence and produces continuous motion.

So the question is not which is newer. It is whether the product needs a position or a speed. A printer carriage wants a stepper. A fan wants a brushless motor.

Six Lines for the Order

These six turn a catalogue page into a specification.

One. Family and frame: inrunner, outrunner or axial, with the diameter and length.

Two. KV with its unit, and whether the figure is rpm per volt or radians per second per volt.

Three. KT, or the current you expect at your working torque.

Four. Sensored or sensorless, and how the product behaves at startup.

Five. The continuous rating with the mounting and airflow it assumes.

Six. The controller, and whether it is supplied and matched. A driver needs a clean supply, and the capacitor that holds a rail steady is part of that.

Two more reads help. If the motor carries a temperature sensor, what a thermistor label really means decides whether the reading means anything. And the spec lines a factory must answer is the format that comes back comparable.

For a motor that ships inside a finished appliance, the CE file for a motor driven product is a separate document again.

Checklist panel of six lines to put on a brushless motor order
Six lines that make two KV figures comparable.
MOTOR CHECK

Send me the datasheet or the listing for the motor you are quoting. I will check whether KV carries its unit, whether KT or a current figure is given, and whether the rating states its mounting. You get a short list of what to ask before the sample order.

Check The Motor

Questions Buyers Ask

What does KV mean on a motor?

It is the unloaded speed divided by the peak voltage at the coils. A motor quoted at 5,700 rpm per volt, fed 11.1 V, would in theory reach 63,270 rpm.

Does a higher KV mean more power?

No. Higher KV means more speed per volt and less torque per amp, because KT is one over KV. Power depends on the motor’s size and how well it sheds heat.

Why does the motor twitch backwards at start?

In a sensorless design there is no back EMF when still, so the controller guesses the phase. If the guess is wrong the rotor turns briefly the other way before it catches up.

Do I need Hall sensors?

Only if the product cannot tolerate a short reverse movement at startup, or must hold position at zero speed. Sensors cost wiring and parts inside the motor.

Are two listings with the same frame the same motor?

Often yes, wound differently. Changing the winding changes KV and leaves the size constant alone, so the frame performs differently at the same current.

Why does my motor overheat at the rated power?

Because the rating came with a mounting condition. In still air, or inside a sealed housing, the heat cannot leave and the usable continuous power is lower.

Questions & Comments

We read every one and reply within 24 hours

If two suppliers quote the same frame at the same KV, ask which winding each one measured. The answers rarely match.

Subscribe
Notify of
guest
0 Comments
Most Voted
Newest Oldest
0
Would love your thoughts, please comment.x
()
x