CCS Charging: Nine Contacts, Two Power Paths
Home
Yiwu, Zhejiang, China
Mon – Fri 9:00 AM – 6:00 PM · Sat 9:00 AM – 4:00 PM
[email protected]

What Is CCS Charging: One Inlet, Two Power Paths

Alan Xiao, Founder of Sourcing Pioneer
Alan Xiao Founder of Sourcing Pioneer
· Updated November 9, 2026 · 9 min read

CCS puts two sockets in one hole, slow and fast.

The letters stand for Combined Charging System. The design takes an existing AC connector and adds two heavy contacts below it for direct current.

That is the whole idea, and it explains the shape. The top half is a normal AC plug. The bottom half is the fast lane.

Studio still life of a CCS charging plug with its cable coiled on a beige surface
The plug carries two very different jobs, and the cable has to survive both.

The Short Answer

CCS is an open charging standard with one vehicle inlet and one plug. The same connector does a slow AC charge overnight and a fast DC charge on a motorway.

There are two versions, and they do not fit each other. CCS1 is built on the North American J1772 plug, with five AC contacts. CCS2 is built on the European Type 2 plug, with seven.

Both add two DC contacts underneath. So CCS2 has nine contacts in total, and CCS1 has seven.

Roughly: a CCS2 inlet accepts a plain Type 2 plug for AC charging. A Type 2 plug will not enter a CCS1 inlet. The two regional versions are not interchangeable, and no simple adapter fixes that.

Nine Contacts, Two Jobs

The layout comes from IEC 62196-3, the connector standard for DC charging. A published industry guide lists it, and it is worth reading as a table rather than a diagram. Each contact either carries power, carries a signal, or does nothing in the mode you are using.

ContactWhat it doesAC modeDC mode
L1, L2, L3Three AC phasesLiveDead
NNeutralLiveDead
PEProtective earthLiveLive
CPControl pilot, the talking pinLiveLive
PPProximity pilot, tells the car what the cable can takeLiveLive
DC+ and DC−The two fast contactsDeadLive

The two fast contacts are visibly larger than the signal pins. That is not styling. A contact carrying hundreds of amps needs metal area to keep the temperature rise inside its limit.

Two numbers come with that table. On the AC side the guide gives up to 63 A per phase at 480 V, or about 43.5 kW. On the DC side it gives up to 1 000 V and 500 A.

The voltage figure explains a lot of marketing. A 350 kW charger assumes a high-voltage battery pack. The same 500 A on a 400 V pack delivers about 200 kW.

That is why two cars at the same station charge at different speeds. The plug did not change. The pack voltage did.

Flat diagram of the nine CCS2 contacts showing which are live in AC and in DC mode
Five of the nine contacts go quiet the moment the car asks for direct current.

What Happens When the Fast Lane Opens

The two power paths never run together. Before any fast charge, the car and the charger agree on a plan, and the AC contacts are switched out of the circuit.

The order is fixed, and it is worth knowing because a fault in the sequence is what burns a plug. The earth connection is checked first. Then the insulation is tested. Only then do the DC contactors close.

The talking happens on the control pilot. In AC mode that pin carries a simple square wave that tells the car how much current is available. In DC mode the same pin becomes a data channel.

Two protocols sit on top of it. Older DC chargers use DIN 70121. Newer equipment uses ISO 15118, which is the standard behind Plug and Charge, where the car identifies itself and the bill follows without a card.

None of this needs the driver to choose a mode. Plugging in a plain Type 2 cable starts AC charging. Plugging in a CCS plug starts the negotiation for DC.

AC modeDC mode
Contacts in useL1, L2, L3, N, PE, CP, PPDC+, DC−, PE, CP, PP
Typical powerUp to 43.5 kW three-phaseUp to 350 kW on a high-voltage pack
What sets the limitThe onboard charger in the carThe pack voltage and the cable cooling

What the Cable Actually Has to Carry

This is where a connector order goes wrong, and the reason is simple. The two modes put current through different wires.

An AC cable carries three phases plus neutral, each sized for tens of amps. A DC cable carries two conductors sized for hundreds. The same plug holds both sets, but no single cable is good at both jobs.

One industry guide puts numbers on the fast case. Above 150 kW the DC side runs 300 to 500 A, and air cooling stops being practical. A liquid-cooled cable is about 20 to 25 mm across, against 35 to 50 mm for an air-cooled cable of the same rating.

That gap is not cosmetic. A 50 mm cable is heavy enough that some drivers cannot lift the plug comfortably, and the strain lands on the inlet.

The driver sees none of it. The screen says charging, the pump starts, and the negotiation has already finished.

That speed hides a failure mode. A plug that is not fully seated can pass a slow AC check and still fail the DC sequence minutes later.

The pin that decides the current

Look again at the proximity pilot. Its job is to tell the car what the cable can take.

A coding resistor inside the plug sets that message. The car reads it, and then limits itself to what the cable claims.

That has two consequences for a buyer. First, a cable rated for 500 A but coded for less will never deliver 500 A, because the car believes the code. Second, a cable coded above its real rating is a fire risk that the car cannot detect.

So the resistor is a specification item, not a detail. Ask for its value in writing, and ask which standard the coding follows.

The rating is a duty cycle

Here is the part most datasheets leave out. The current a cable can carry is not one number, because heat builds and then drains.

The industry body behind CCS has published a proposal for short-term boost current. It defines three things: a rated boost current, how long the boost may last, and how long the cable must cool before the next one.

It also adds a temperature rise test for the cable assembly, so the three numbers are proven on hardware rather than assumed.

Read a cable datasheet with that in mind. A single amp figure, with no duration and no cooling time, describes a laboratory moment rather than a working day at a busy station.

Flat panel comparing air cooled and liquid cooled DC cable diameter and rating
Same rating, two diameters. The cooling method decides how heavy the plug feels.

At Home, the Cable Is Not the Limit

Buyers often assume a heavier cable charges faster. On the AC side that is not true, and the reason sits inside the car.

AC power passes through an onboard charger before it reaches the battery. That unit has a rating, and nothing in the cable can exceed it.

A car with an 11 kW onboard charger draws 11 kW from a 22 kW station. A thicker cable changes nothing, because the bottleneck is behind the inlet.

Three-phase supply is the other half. On a single-phase supply the same car may take a third of that figure, whatever the plug says.

So the useful question for a home product is not the cable rating. It is what the car can accept, and what the building can supply.

Tethered or Socketed

Two station designs change who owns the cable, and the choice affects returns more than specifications do.

A tethered station keeps the cable attached. The operator controls the whole assembly, including the seal and the strain relief, and the user cannot substitute a cheaper cable.

A socketed station carries only a socket. The driver brings a cable, which means the seal and the pilot coding are now outside the operator’s control.

Both designs face the same field problem. Cables are stolen for their copper, and the industry body has published a white paper on cable theft at charging stations.

That paper looks at site layout, monitoring and traceability rather than connector design. For a buyer it is a reminder that the cable is an asset on a pole, not only a part number.

Seals, Cycles and Weather

The same guide gives the mechanical side, and these numbers decide returns rather than performance.

A CCS2 connector is rated around 10 000 mating cycles. The seal is rated IP44 while mated, and IP55 with the cap on and the plug out.

Those two ratings are often confused in a listing. IP44 mated means water splashing on a connected pair is tolerated. It says nothing about a plug lying in a puddle with its cap off.

Retention matters as much as the seal. A latch that wears early leaves the plug half seated under load. A half-seated DC contact then heats at the tip, not along the barrel.

The working temperature range is quoted from −30 to +50 °C. A station in direct summer sun can sit above that, and a dark cable in the sun runs hotter than the air around it.

One Standard, Three Markets

The plug you build depends on the market, and the split is regional rather than technical.

Europe settled on CCS2, and the guide reports a rule that made it unavoidable. New public chargers in the European Union must offer a CCS2 outlet.

North America uses CCS1, but the ground is moving. A second standard is taking over there, built on a single connector that handles both AC and DC.

China runs its own connector family, similar in concept and different in metal. Japan kept CHAdeMO for older cars while adding CCS on newer models.

It also means a supplier cannot swap one plug for the other at the end of the line. The AC base changes, the pilot wiring changes, and the housing around both changes. That is new tooling, not a new label.

Plan for two part numbers if you sell into both regions. One mould cannot serve both, and a shared drawing invites a mixed shipment.

So a connector programme starts with one question. Which market, and which inlet will the cable meet. Everything after that is engineering.

Six Lines for the Order

A CCS cable order that names only a power figure gives the factory room to choose the rest. Six lines close that gap, and they fit the same sheet you send a factory for any other part.

Flat card listing the six lines of a CCS cable order
Six lines. Each one removes a choice from the factory floor.

One. Name the regional version and the inlet it mates with. CCS1, CCS2, or both as separate part numbers.

Two. Give the DC class as voltage and current, not as kilowatts. The kilowatt figure depends on the vehicle pack, as the numbers above show.

Three. Specify the cable: length, conductor size, and whether it is air or liquid cooled.

Four. Put the proximity pilot coding in writing, with the resistor value and the standard it follows.

Five. Demand the temperature rise report, plus the boost duration and the cooling time if a boost rating is claimed.

Six. State the seal rating mated and unmated, and the mating cycle count with the test that proves it.

None of these lines needs a laboratory to write. Each one removes a choice from the factory floor.

The same discipline applies to the water side of the claim. A connector rating of IP44 mated is a narrow promise. The way that rating is tested is set out in how an IP code is proven.

One more check belongs on the electrical side. Before the DC contactors close, the equipment runs an insulation test, which is a different question from the one a charging cable answers.

For a product sold in Europe, the whole package still has to sit behind a declaration of conformity. The CE file covers how that paperwork is built.

CABLE CHECK

Send me the cable spec you were quoted, or the inlet drawing. I will tell you whether the current class, the pilot coding and the cooling method are all named, and which line is missing before tooling starts. No cost, no obligation.

Check My Cable

Questions Buyers Ask

Is CCS the same as a Type 2 plug?

No. Type 2 is the AC connector. CCS2 uses it as the top half and adds two DC contacts below. A Type 2 plug fits a CCS2 inlet for slow charging, but it cannot fast charge.

Can a CCS1 cable work on a CCS2 car?

Not directly. The two versions have different AC bases and are not intermateable. A simple adapter cannot bridge them, because the communication and the contact geometry differ.

Does a 350 kW charger always deliver 350 kW?

No. The limit is the pair of them. A charger rated 500 A delivers the full figure only into a high-voltage pack. On a 400 V pack the same current gives about 200 kW.

Why does a fast charging cable need liquid cooling?

Because heat builds in the conductor. Above roughly 150 kW the current reaches hundreds of amps, and an air-cooled cable of that rating becomes thick and heavy. Liquid cooling keeps the diameter down.

What does the proximity pilot actually do?

It tells the car what the cable is rated for. The car reads it and limits itself. A code that understates the cable caps the charge, and a code that overstates it hides a risk.

Is an IP44 rating enough for an outdoor charger?

It is a narrow claim. IP44 mated covers splashing on a connected pair, not a plug resting in water with its cap off. The unmated rating and the cap design decide that case.

Questions & Comments

We read every one and reply within 24 hours

If the quote names a kilowatt figure and nothing else, send me that line. I will say what the cable still has to prove.

Subscribe
Notify of
guest
0 Comments
Most Voted
Newest Oldest
0
Would love your thoughts, please comment.x
()
x